HCHandCalc

Two-Hinged Parabolic Arch — Concentrated Load

Arches · Two-Hinged Parabolic Arch · Pinned Bases, No Crown Hinge · Indeterminate to the First Degree · Vertical Point Load at Any x
Worked example

This page shows the complete calculation with example values: the inputs, the results and every step in between.

The interactive calculator is part of HandCalc Pro. With Pro you can enter your own values, switch between SI and Imperial units and download the technical report as PDF or Word.

1

Geometry and load

Span, rise, and a vertical point load at distance a from A
m
m
kN
m
0 10 m 20 m
Model: A and C are pinned, no crown hinge — one redundant (H), recovered from compatibility with the classical assumption I = I₀·secφ (so ds/I = dx/I₀; axial strain neglected). Arch axis: y(x) = 4f·(x/ℓ)·(1−x/ℓ). Sign convention: M positive when the intrados (inside face) is in tension; N positive in compression.
2

Reactions and horizontal thrust

Vertical reactions as for a simple beam; H from compatibility (strain energy) — closed form
RAvertical, at the near support = P·bℓ = 100×15/20 = 75kN
RCvertical, at the far support (b = ℓ − a) = P·aℓ = 100×5/20 = 25kN
H∂U/∂H = 0 → H = ∫M₀·y·dx ÷ ∫y²·dx — with k = a/ℓ = 5Pℓ8f·(k − 2k³ + k⁴) = 5×100×20/(8×4)×0.2227 = 69.58kN
∫y²dx = 8f²ℓ/15 and ∫M0·y·dx = (Pf ℓ²/3)·(k − 2k³ + k⁴) give the closed form. Symmetric in k ↔ 1−k; maximum 25Pℓ/(128f) at the crown — 22 % less than the three-hinged value Pℓ/4f. With constant EI instead of I₀secφ the thrust changes by well under 1 % (constant EI: H = 69.78 kN, 0.29 %).
3

Bending moment (M)

M(x) = M0(x) − H·y(x) — no longer zero at the crown; extremes located along the axis
M(x)M0 = simple-beam moment; y = arch height at x
= RA·x − H·y(x)0 ≤ x ≤ a = RC·(ℓ − x) − H·y(x)a ≤ x ≤ ℓ
Mmax+at x = 5 m (under the load) = max M(x) = 166.26kN·m
Mmax−at x = 14.5 m (unloaded side) = min M(x) = -84.46kN·m
M = 0 only at A and C — the crown carries moment (M(ℓ/2) = M₀(ℓ/2) − H·f = -28.32 kN·m). The positive peak sits under the load; the negative extreme lies on the unloaded side, its position found by evaluating M(x) at 1000 stations.
Bending Moment Diagram (M) — drawn on the tension side
PM⁺ = 166.26 kN·mM⁻ = -84.46 kN·mx=8: M=32.81 kN·mblue: positive (intrados in tension) · red: negative (extrados in tension)
4

Shear (V) and axial force (N)

Resolved along the arch tangent — both jump at the load
V(x), N(x)V0 = simple-beam shear (RA left of the load, RA − P right of it); tanφ = (4f/ℓ)(1−2x/ℓ)
V = V0·cosφ − H·sinφshear, normal to the axis N = H·cosφ + V0·sinφaxial, compression positive
NAat support A, φA = atan(4f/ℓ) = H·cosφA + RA·sinφA = 101.19kN
NCat support C = H·cosφA + RC·sinφA = 69.95kN
Ncrownx = ℓ/2, φ = 0 = H = 69.58kN
ΔVjump in shear at the load, x = a = P·cosφ(a) = 92.85kN
Vcrownx = ℓ/2 — equals V0 there, since φ = 0 = -25kN
N stays compressive along the whole arch; its largest value is at the support on the loaded side. The axial jump at the load is P·sinφ(a). Vcrown = V0(ℓ/2) is the same as for the three-hinged arch; Ncrown = H is lower.
Shear Force Diagram (V) — along the arch axis
PV⁻ = 43.79 kNV⁺ = -49.05 kN15.1 kN23.94 kNx=8: V=-35.68 kNV jumps by P·cosφ at the load
Axial Force Diagram (N) — along the arch axis
PN = 101.19 kNN = 69.95 kNN = 69.58 kN (crown)x=8: N=64.76 kNred: compression throughout
5

At a given section

Read the values at any x — marked in amber on the diagrams
m
0 10 m 20 m
y(x)arch height at this section = 3.84m φ(x) = 9.1°
M(x)= M0(x) − H·y(x) = 32.81kN·m
V(x)= V₀·cosφ − H·sinφ = -35.68kN
N(x)= H·cosφ + V₀·sinφ — compression = 64.76kN