In short
- The horizontal thrust of an arch under uniform load is H = wL2/8f: the simple-beam moment divided by the rise.
- A parabolic arch under a load that is uniform along the span is in pure compression; any other load adds bending.
- Halving the rise doubles the thrust, so flat arches need strong abutments or a tie.
Why an arch works
A beam resists load by bending: the top fibres are compressed, the bottom ones stretched. An arch replaces that internal couple with a geometric one. The supports push inward with a horizontal force H, and because the arch axis rises by y above the supports, the thrust produces a moment Hy that opposes the moment of the loads. At any section:
where M0 is the moment that a simply supported beam of the same span would have under the same load. When the shape of the arch is proportional to M0, the two terms cancel everywhere and the arch carries the load in pure compression. Such a shape is called funicular for that load — the shape a hanging cable would take, turned upside down.
- A parabola is funicular for a load uniform along the horizontal span (a deck hung from or resting on the arch).
- A catenary is funicular for a load uniform along the arch itself, such as its own weight.
- A circle is funicular for uniform radial pressure, as in a buried pipe or a dome under water.
Three-hinged arches: statically determinate
With hinges at both springings and at the crown, the arch has four reaction components (two at each support) and four equations: the three of equilibrium and the condition that the moment at the crown hinge is zero. For a crown hinge at mid-span this gives directly:
Because a three-hinged arch is determinate, temperature changes, support settlement and shrinkage cause no internal forces: the arch simply rises or drops at the crown. That is why the form is popular for timber and steel halls on uncertain ground.
Worked example
The free three-hinged parabolic arch calculator uses span L = 20 m, rise f = 4 m and w = 10 kN/m:
The axis leaves the support at an angle of arctan(4f/L) = arctan(0.8) = 38.7°, and the resultant of H and V points exactly along it — which is another way of saying that there is no bending. The moment is zero along the whole arch.
Half-span loading: where bending comes from
Snow drifting on one side, or traffic on half a bridge, breaks the funicular match. For a three-hinged parabolic arch with the uniform load on the left half only, the thrust halves to wL2/16f, and at the quarter points:
For the example above that is ±62.5 kN·m — small compared with the 500 kN·m that a 20 m simple beam would see, but not zero. The arch section must be designed for this bending together with the compression, and the unbalanced case often governs.
Rise-to-span ratio
The thrust is inversely proportional to the rise. With the same 20 m span and load, a rise of 2 m gives 250 kN of thrust and a rise of 8 m only 62.5 kN. Typical ratios f/L lie between 1/8 and 1/4. Flat arches save height but need heavier abutments, or a tie between the springings that takes the thrust in tension so the supports only carry vertical load — the tied arch common in bridges and roof trusses.
Two-hinged and fixed arches
Removing the crown hinge makes the arch statically indeterminate. The thrust then follows from compatibility: the supports do not move apart. For a parabolic two-hinged arch under full uniform load, with the usual assumption that the section stiffness varies as I = I0 sec φ and axial shortening is neglected, the result is again H = wL2/8f. The differences appear elsewhere:
- A two-hinged arch is stiffer than a three-hinged one under unbalanced load, but a rise in temperature, elastic shortening of the arch or a small spreading of the supports changes the thrust and induces bending.
- A fixed arch is three times indeterminate. It has the smallest deflections and moments under live load, but moments develop at the springings, and it is the most sensitive to settlement and temperature. It needs rock or very stiff foundations.
What the calculators do not cover
Slender arches can buckle in their own plane or sideways under compression long before the material is fully stressed. Masonry arches must keep the line of thrust inside the middle third of the section to avoid opening joints. Both checks are outside the scope of a first-order hand calculation and must be made separately.