HCHandCalc

Three-Hinged Gable Frame — Vertical and Horizontal Load

Frames · Three-Hinged Gable Frame · Pinned Bases + Crown Hinge · Statically Determinate · Combined UDL + Horizontal Point Load
Worked example

This page shows the complete calculation with example values: the inputs, the results and every step in between.

The interactive calculator is part of HandCalc Pro. With Pro you can enter your own values, switch between SI and Imperial units and download the technical report as PDF or Word.

1

Geometry and loads

Span, eave/crown height, vertical UDL and horizontal point load
m
m
m
kN/m
kN
Define different section inertia / elastic modulus for column and rafter
Model: Bases A and D are pinned, and a THIRD hinge sits at the crown (E) — the system is STATICALLY DETERMINATE (not indeterminate). Reactions follow from equilibrium alone plus the crown condition (ME=0); no section inertia or elastic modulus (E, I) is needed at all. w (per unit horizontal length, the usual snow/roof-load convention) and P (horizontal, at eave B, representing wind) are combined by superposition — either one may be left at zero.
2

Reactions

Direct from equilibrium + crown condition (closed form)
Contributionshorizontal/vertical component produced separately by each load type
Hw=wℓ²/[8(h+r)]  ·  HA,P=P(h+2r)/[2(h+r)]  ·  HD,P=Ph/[2(h+r)]
45 kN 13.33 kN 6.67 kN
Rx,A= Hw − HA,P (superposition) = +31.67kN
Rx,D= −(Hw + HD,P) = -51.67kN
Ry,A= wℓ/2 − hP/ℓ = +83.33kN
Ry,D= wℓ/2 + hP/ℓ = +96.67kN
Because this frame is STATICALLY DETERMINATE, Hw and HA,P/HD,P depend on GEOMETRY only — the column/rafter stiffness ratio (kr) never appears. For w>0, H acts INWARD at both supports (arch-like thrust); for P>0, both supports pick up a −x contribution (resisting the wind); the net sign depends on which load governs.
3

Bending moments

Eave corners (B, C) and the crown hinge (E)
Mcorner,B= |Rx,A|·h = 126.67kN·m
Mcorner,C= |Rx,D|·h = 206.67kN·m
Mcrown (E)— by definition, a hinge = 0 (always, exactly)
In each column, the moment is zero at the base (hinge) and grows linearly to Mcorner (depending only on that column's own horizontal reaction — the same general "Vcolumn×h" rule as in Types 1/2/6/7). Thanks to the third hinge at the crown, Mcrown is exactly zero under EVERY load combination — a built-in check you can use to verify the result.
Bending Moment Diagram (M) — on the frame
+126.67+206.67Mₘ=0 (hinge)
4

Shear and axial force

V, N in columns and rafters
Column AB · Column CD
VAB=31.67 kN NAB=83.33 (compression) kN
VCD=51.67 kN NCD=96.67 (compression) kN
Rafter B-E(eave B → crown E)
NB=75.37 (compression) kN VB=62.72 kN
NE,left=46.91 (compression) kN VE,left=22.66 kN
Rafter E-C(crown E → eave C)
NE,right=51.12 (compression) kN VE,right=10.01 kN
NC=79.58 (compression) kN VC=75.37 kN
N and V on a rafter are found by projecting the forces to the left of the cut onto that rafter's local axis (tangential/normal). At the crown (E), the LEFT and RIGHT values are generally DIFFERENT — a natural consequence of the roof slope changing direction at E (even with no point load applied there). Positive N = compression.
Shear Force Diagram (V) — on the frame
V=31.67V=51.6762.7275.37 kN
Axial Force Diagram (N) — on the frame
N=83.33 kN (compression)N=96.67 kN (compression)75.3779.58 kN